SX-Series

Tomy

1

Saving the installation space

The main body is very compact owing to the design which provides thorough installation space saving. In addition, installation space at the side of the main body which is required for models employing a slide-open lid, which is not necessary at SX autoclaves top-open lid. Even when several SX autoclaves are installed side-by-side, the necessary installation space is minimized.

A : 790mm(SX-300),970mm(SX-500),1003mm(SX-700)
B : 614mm(SX-300),794mm(SX-500),827mm(SX-700)
C : 410mm(SX-300/500),470mm(SX-700)

2

Easily viewable “work monitor”

The LED display shows working status for easy monitoring. The process being performed is indicated by an LED indication lamp blinking in red.

The illuminated display on the operating panel shown in the picture is different from the actual display at the time of operation.

Cooling fan provided as a standard feature

A rapid air-cooling function (vessel-cooling fan) permitting reduction of chamber cool down time is provided as a standard feature. This is most appropriate for lowering the temperature rapidly on completion of the cycle. The time required for lower the temperature is much reduced by employment of the cooling fan in comparison with natural cooling.

Sterilizing course selection

The optimal sterilizing course can be selected from among five courses, such as the liquid sterilizing course in addition to that for normal sterilization.

3

Other features

Large indication lamp “Operated”

An easily viewable large indication “Operated” is provided at the upper section of the operating panel.
Depending on the pressure status (normal pressure/pressure is applied),the displayed color changes.

Setting to 100°C is possible.

Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).

Auto-variable exhaust speed

A function allowing the exhaust valve to open automatically after completion of sterilization is provided. The exhaust speed can be set to one of six levels (set to variable for liquid sterilization)

Timer function

The operation starting time can be preset easily. By presetting the start of operation, otherwise wasted periods at night or early morning, can be used effectively.

Setting to 100°C is possible.4

Variable temperature setting such as to 100°C as well as to 121°C has been made possible.The temperature can be set within the range from 45°C to 135°C in steps of one degree (heating mode up to 104°C).

Lid interlock

A safety device (lid interlock mechanism) for locking the lid during operation is provided. A high level of safety is assured to prevent unanticipated accidents.

Pressure fine adjustment function

When the balance between the temperature and pressure deviates during sterilization, fine exhausting is carried out automatically in order to adjust the best chamber condition.

Functions & Features
Liquid sterilizing / Heating / Warming / Check / Last-run memory / Built-in steam exhaust bottle
Flat internal surface of the chamber / Lid opening/closing detection mechanism
Exhaust bottle detection mechanism / Leakage breaker provided

OPTION

External sensor for the articles to be sterilized

5

 

Sensor for directly detecting the temperature of articles to be sterilized. More reliable sterilization monitor can be carried out.

Data output

6

The temperature data, pressure data, etc. can be exported. The temperature can be recorded when the external recorder is connected.

External sensor and recorder

7

A temperature sensor and recorder independent of the autoclaves. The chamber temperature can be recorded.


SX Specifications

Model name
SX-300
SX-500
SX-700
Operating temperature range
Sterilizing
105 ∼ 135°C(0.019 ∼ 0.212MPa)
Heating
45 ∼ 104°C(0 ∼ 0.015MPa)
Warming
45 ∼ 95°C
Maximum operating pressure
0.263MPa
0.25MPa
Temperature
Display
Digital
Pressure gauge
Display
Analog
Display range
0 ∼ 0.4MPa
Heat source
1.5kW electric heater
2kW electric heater
3kW electric heater
Safety device
• Water level sensor, • Current leakage breaker, • Lid interlock, • Over-heat prevention, • Over-pressure prevention, • Open temperature sensor detection, • Safety valve
Time
Display
Digital
Display
range
Sterilizing
0:00 – 9:59, 0 – 99hours, 0 – 999min.(0:00 – 9:59,10 – 99hours changeable)
Heating
Warming
Variable: 0 – 99hours
Chamber dimensions
φ325 x 553mm
φ325 x 733mm
φ370 x 774mm
Chamber capacity
Effective internal
volume:36L,
Internal volume:44L
Effective internal
volume:50L,
Internal volume:58L
Effective internal
volume:69L,
Internal volume:79L

Chamber material

SUS304

Dimensions (mm)
410W x 477D x 790Hmm
(With protruding:574D)
410W x 477D x 970Hmm
(With protruding:574D)
470W x 528D x 1003Hmm
(With protruding:625D)
Weight
50kg
60kg
72kg
Rated voltage
120V AC
230V AC
Power input
13A/120V
17A/120V
7A/230V
9A/230V
13A/230V
Required power supply
Single-phase 120V AC
(50/60 Hz)15A or more
Single-phase 120V AC
(50/60 Hz)20A or more
Single-phase 230V AC
(50/60 Hz)10A or more
Single-phase 230V AC
(50/60 Hz)15A or more
Single-phase 230V AC
(50/60 Hz)15 A or more
Power consumption (calorific value)
1.5kW (1290kcal/h)
2.0kW (1720cal/h)
3.0kW (2580cal/h)
Environmental Conditions
When opereting the autoclave, observe the environmental conditions given below.
Ambient temperature: 10 to 35°C
Almospheric pressure: 860 to 1060hPa
Relative humidity: 30 to 85%
Maximum gradient: 2
Accessories
Stainless baskets 1
(φ300 x 182mm)
Stainless baskets 2
(φ300 x 182mm)
Stainless baskets 2
(φ345 x 181mm)
• Chanber bottom Plate 1, • Caster stoppers 4, • Operator’s Manual 1, • Clear folder (for storing the operation manual) 1, • Screw (for attaching the clear folder) 1, • Warranty card 1, • Customer card 1, • Inspection Sheet 1

ES-Series

Tomy
1

Reliable & Speedy Sterilization

A top-open lid, which can be operated easily with a single hand or foot, is provided with the SX autoclaves. To open the lid, the lid lock is released by stepping on the foot pedal locates at the bottom while pressing the lid down. The lid can be opened with minimal effort owing to mechanical assistance. In addition, the lid can be closed easily just by pressing it down.

User-friendly Memory Function

Once turned on the system automatically sets and displays a pre-set value. Operation is done simply by pressing the start switch. ES-315/ES-215 enables the set temperature and time for each mode program to be stored in its memory.

3

*The control panel lighting image shown above may vary from actual display.

MODE/PROCESS display enables real time monitoring of operation status.

ES-315 / ES-215 offers three mode programs.

5Sterilization Mode
It contains a delay start timer function that allows operation to start 1 to 99 hours later.

 6Sterilization/warming Mode
This mode is useful when not removing culture media from the autoclave immediately after sterilization. Sterilized media can be kept warm to prevent coagulation.
 7Heating Mode
This mode program automates the dissolution of culture media that can sometimes be a painful process when using a water bath to boil them.

User-friendly design allows for even more easy maintenance.

Chamber having a flat inner surface

All models are supplied with stainless steel wire mesh baskets. No protrusions on inner surface of the chamber enable smooth loading and unloading of the basket as well as block design of all pipe fittings ensures safe operation.

Front access for easy maintenance

The exhaust bottle to capture and store exhaust steam is placed on the front panel of the autoclave unit. Access to the chamber for replacing water inside, as well as for routine maintenance and inspection, is done on the front of the unit, which also permits operators to replace bellows, saving costs for services by the service personnel.

A microprocessor controlled monitoring system provides safe sterilization.

Incomplete sterilization protection

In case of abnormal chamber temperature rise, the autoclave stops its operation. In case of abnormal decrease in temperature, the sterilization timer is temporarily suspended and then reactivated when the set temperature is reached.

Chamber overpressure protection

If overpressure in the chamber is detected, the autoclave stops all the function and indicates an error message simultaneously.

Chamber interior overtemperature protection

If the temperature inside the chamber exceeds the set temperature by 5°C or more, the autoclave stops all the function and indicates an error message simultaneously to avoid overheating.

Chamber exterior overtemperature protection

The thermostat switch detects the temperature of chamber exterior wall, which allows the autoclave to stop all the function if the temperature exceeds 130°C.


Specifications

Model

ES-215

ES-315

Operating temperature range
(during sterilizing)

105 – 123°C

105 – 132°C

Operating pressure range

0 – 127kPa

0 – 186kPa

Maximum operating pressure

147kPa

216kPa

Temperature control

Digital, microprocessor controlled

Temperature display / display range

Digital / -15 – 180°C

Pressure display / display range

Analog / 0 – 250kPa

Analog / 0 – 400kPa

Heat source

1.5kW electric heater

2.0kW electric heater

Timer control

Digital, microprocessor controlled

Timer display

Digital

Timer
display range

Sterilizing mode:

1 – 240min. or continuous

Sterilizing-warming mode:

1 – 240min. (sterilizing) / 1 – 8hours (warming)

Heating mode:

1 – 8hours

Start-timer setting range

1 – 99hours in each operation mode

Memory function

A set of temperature and time setting in each operation mode

Safety devices

• Inside the chamber overheat prevention, • Outer wall of the chamber overheat prevention, • Overpressure prevention, • Temperature sensor disconnection prevention, • Empty heating prevention, • Leakage breaker, • Safety valve

Malfunction prevention devices

• Low water level detection, • Exhaust valve knob open/close detection,
• Insufficient sterilization detection, • Chamber lid open/close detection

Leakage
breaker

Rated breaking current:

20A (120V) , 15A (220 / 230 / 240V)

30A (120V) , 15A (220 / 230 / 240V)

Rated sensed current:

30mA (120V) , 10mA (220 / 230 / 240V)

Protection type

Class 1 equipment

Operating
environment

Ambient temperature:

5 – 35°C

Relative humidity:

30 – 85%

Atmospheric pressure:

700 – 1060hPa

Gradient:

Within 2°

Dimensions

φ248 x 543mm

φ325 x 740mm

Usable dimension

φ236 x 450mm

φ312 x 635mm

Capacity of chamber

22ℓ

53ℓ

Chamber material

SUS304

Capacity / material of exhasut bottle

3ℓ / polyethylene

Type / material of lid gasket

Accommodating internal pressure / silicone rubber

Dimensions of main unit (mm)

400W x 460D x 920H (Height from floor to control panel:705)

490W x 560D x 1090H (Height from floor to control panel:875)

Net weight

50kg

80kg

Rated Voltage

AC 120 / 220 / 230 / 240V

Power input

15A (120V), 7A (220 / 230 / 240V)

20A (120V), 10A (220V), 9A (230 / 240V)

Power supply requirements

Single-phase 120V AC (50 / 60Hz) 15A or above

Single-phase 120V AC (50 / 60Hz) 20A or above

Single-phase 220 / 230 / 240V AC (50 / 60Hz) 15A or above

Power Comsumption (calorific value)

1.5kW (1290kcal/h)

2kW (1720kcal/h)

Accessories

• Stainless steel basket with slatted bottom plate 1, • Water level sensor 1,
• Inspection sheet 1, • Warranty card 1, • Customer card 1, • Operator’s manual 1,
• Clear plastic accessory case 1, • Attachment screw for clear plastic accessory case 1

Stainless basket 1 (φ224 x 376mm)

Stainless basket 2 (φ300 x 182mm)