centrifuge

NIX 521

Tomy

NIX-521, a dual-temp centrifuge that combines functions of refrigerated centrifuge and thermostatic centrifuge provide wide temperature setting range (-9℃ to 42℃). Thermostatic function with centrifuge is used for application such as “Gene transfer to hemopoietic stem cell” and “Development of vector for anti-cancer immunity”.

Accessories here

NIX-521 has function of air circulation, which left heated air in and out from bottom of chamber lid. Because of these inlet and outlet of air at bottom of chamber lid, no heater element is in chamber for safety.

Features

Three-step acceleration and three-step and natural deceleration

Initial values for acceleration and deceleration characteristics are set from 0 to 500rpm, however, they can be varied up to maximum speed in 100rpm increments by function settings.

ECOmode

Activating the power-saving [ECO] mode can also help reduce the power consumption during the waiting time (standby cooling) by allowing the temperature control bands to be changed.The chamber can cool down to the set temperature within approximately 3 minutes and a half (*) after release from ECO mode.

* Under the conditions: set temperature of 4℃ at an ambient temperature of 25℃.

[ECO] MODE OFF [ECO] MODE ON
POWER CONSUMPTION 54Wh POWER CONSUMPTION 47Wh<13%DOWN>

From micro tubes to 250ml bottles

The NIX-521, with the ability to accommodate micro tubes to 250ml bottles or deep well plates, is ideal for wide range of applications. Using an optional bucket cap kit B433HS*, various types of rotors including swinging bucket rotors of biohazard-proof can be mounted.

Convenient flashing function

Convenient flashing function allows operation with preset centrifuging conditions.

*Bucket cap kit B433 is an optional kit.
HS This highly sealed rotor, which has been tested and certified by the Health Protection Agency (HPA, UK) to be compliant with the International Standard (Annex AA of the IEC 61010-2-020), meets requirements for biohazard safety. [Bucket cap kit B433] is an optional kit.

Easy to see and operate control panel

1.
Easy-to-see LCD monitor display shows various information including remaining run time, error messages, rotor types in use and records of centrifugal operation. The monitor can display in English or Japanese.

*Indication displays on the control panel in the photo is different from displays of actual operation.

2.
Dual color LED display allows the user to monitor the operation status just by looking the display; red indicates that the rotor is spinning while green indicates the rotor is stopped.

3.
Popular user-friendly Jog Dial equipped with an <ENTER> button on top enables setting to be changed quickly and more surely.

Safety & Ecology

Flap-drive system for safer and more efficient operation

Innovative Flap-drive system employed to maintain safe and efficient centrifugal operation allows a margin of error and eye-balancing of sample tubes.
*Some rotors are excepted.

  • Non-chlorine, ozone-friendly refrigeration medium which has zero ozone layer destruction coefficients is adopted.

Flex-Spin Drive

The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.

One-push rotor locking knob

With a single knob push, the rotor can be quickly and securely fixed.
*Some rotors are excepted.

Wide variety of rotors

Angle Rotors Spinning maximum 10,000rpm (Angle rotors only).
Swing Out Rotors From micro tubes to 250ml bottles.

Specifications

Model NIX-521
Maximum Speed 10,000rpm
Maximum RCF 11,740G
Maximum Capacity 1,536ml (Deep-well plate x 8)
Control System Microprocessor control (feedback system)
Drive Motor Induction motor
Drive System Flex-Spin drive system (Direct drive with an automatic alignment function)
Data Entry Jog Dial equipped with an <ENTER> button
Temperature Setting Range From -9℃ to +42℃ (1℃ increment)
Speed Setting Range 100 to 10,000rpm (100rpm increments)
RCF Setting Range 10 to 11,740G (10G increments for the range less than 300G,
100G increments for the range over 300G)
Time Setting Range From 10 sec to 50 sec, in 10 sec increments, from 1 min to 99 min, in 1 min increments
or <F–> for free
Safety Devices • Imbalance detector, • Lid interlock, • Lid open/close detector, • Abnormal speed detector,
• Over-current circuit breaker, • Rotor identification system, • Motor over-current detector,
• Abnormally high or low chamber temperature detector
Additional Functions • Three-step acceleration characteristics selection, • Three memory function,
• Three-step deceleration characteristics selection, • FLASH (momentary spin) function,
• Memory function for last run parameters, • BART Code selection, • Power saving (ECO) mode
Refrigerant HFC R404A (270g)
Rated Current 6.5A
Power Requirements 1-Phase 50/60Hz AC220/230/240V 8A
Power Consumption(Heat output) 1,050W (903kcal/h)
Breaker Rated breaking current 7.5A
Protection Against Electric Shock Class I
Dimensions
(except protruding portion)
540W x 597D x 858H mm,
(table height; 750mm)
Net Weight 118kg
Environmental Requirements Ambient temperature range:10 to 35℃, Relative humidity:30 to 85%,
Atmospheric pressure:700 to 1,060hPa
Intended exclusively for use indoors, Overvoltage category: II, Pollution degree: 2
Accessories Included • Operator’s manual 1, • Warranty Card 1, • BART Cord table 1,
• Clear storage case for operator’s manual 1, • Attaching screw for clear storage case 1,
• Power cord×1pc., • Spanner 1, • Level gauge 1, • Rotor locking knob 1, • Drain plug 1

※Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.

See Catalog PDF for details.

* This document is created in the PDF file format.
* To view PDF files, Adobe Reader or other software is needed.
* If you don’t have Adobe Reader, click here to download its latest version.
PDF downroad NIX-521 (1.4MB)

LCX Series

Tomy
[Centrifuges]LCX-200/100

LOW SPEED BENCH-TOP CENTRIFUGE LCX-200/100

  • LCX-200LCX-200                      LCX-100LCX-100

Accessories here

Features

Mix Bucket & Mix Rack & Multi Rack

Three-step acceleration and three-step and natural deceleration

Initial values for acceleration and deceleration characteristics are set from 0 to 500rpm, however, they can be varied up to maximum speed in 100rpm increments by function settings.

From microtubes to 250ml bottles

LCX-200/100, with the ability to accommodate microtubes to 250ml bottles or deep well plates, are ideal for wide range of applications. Using an optional bucket cap kit B433 HS*, various types of rotors including swinging bucket rotors of biohazard-proof can be mounted.

Convenient flashing function

Convenient flashing function allows operation with preset centrifuging conditions.

*Bucket cap kit B433 is an optional kit.
HS This highly sealed rotor, which has been tested and certified by the Health Protection Agency (HPA, UK) to be compliant with the International Standard (Annex AA of the IEC 61010-2-020), meets requirements for biohazard safety. [Bucket cap kit B433] is an optional kit.

Easy to see and operate control panel

Easy-to-see LCD monitor display shows various information including remaining run time, error messages, rotor types in use and records of centrifugal operation.
control panel

*Indication displays on the control panel in the photo is different from displays of actual operation.

Dual color LED display allows the user to monitor the operation status just by looking the display; red indicates that the rotor is spinning while green indicates the rotor is stopped.
the display: rotor is spinning and stopped.

Safety & Convenience

Flex-Spin system for safer and more efficient operation

Innovative Flex-Spin system employed to maintain safe and efficient centrifugal operation allows a margin of error and eye-balancing of sample tubes.
*Some rotors are excepted.

• LCX-200/100 are equipped with a function to automatically reduce the rotation speed and shut the system down if it is being run over the imbalance tolerance limit.

Flex-Spin Drive [Sample Movie]

The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.

One-push rotor locking knob

With a single knob push, the rotor can be quickly and securely fixed.
*Some rotors are excepted.

One-push rotor locking knob diagram

Safety & Convenience Chamber Lid

The hand guard device is equipped to prevent operator’s hand and fingers from getting caught by the chamber lid.
The operator can open / close the lid and load / unload the sample tubes even though during the main power switch off.

Hand Guard Device

Compatible rotor line-up with TOMY CAX/AX/NIX-Series centrifuges

LCXシリーズはフロアタイプの多本架遠心機シリーズと共通シャフトを採用しているので、ローターの互換性があります。

LCX-Series equip common shaft with other TOMY floor type centrifuges. Various compatible rotors can be used as following centrifuges.

CAX-571
AX-521/511/501
NIX-521

※ Some of combinations of centrifuge, rotor, bucket and rack are not compatible.

Accessories here

Specifications

Model LCX-200 LCX-100
Maximum Speed 10,000rpm
Maximum RCF 11,740G
Maximum Capacity 1,000ml (250ml x 4)
Speed Control System Microprocessor feedback control
Drive Motor Induction motor
Drive System Flex-Spin drive system (Direct drive with an automatic alignment function)
Data Entry Jog Dial equipped with an <ENTER> button
Speed Setting Range 100rpm to 10,000 rpm(100rpm increments)
RCF Setting Range 10 G to 11,740 G
(Less than 300G : 10G increments, Over 300G : 100G increments)
Time Setting Range From 10 sec to 50 sec, in 10 sec increments,
from 1 min to 99 min, in 1 min increments or <F-> for free
Safety Devices • Imbalance detector • Lid interlock • Lid open/close detector • Abnormal speed detector • Over-current circuit breaker • Rotor identification system • Motor over-current detector
Additional Functions • Three-step acceleration characteristics selection • Three-step deceleration characteristics selection • Three memory function • FLASH (momentary spin) function • BART Code selection • Memory function for the last run parameters
Rated Current 120V : 10A
220/230/240V : 6A 220/230/240V : 4A
Power Requirements 1-Phase AC120V 60Hz 15A
1-Phase AC220/230/240V 50/60Hz 8A 1-Phase AC220/230/240V 50/60Hz 8A
Power Consumption(Heat output) 660W (568kcal/h) 430W (370kcal/h)
Breaker Rated breaking current 120V : 15A
Rated breaking current 220/230/240V : 7.5A Rated breaking current 220/230/240V : 7.5A
Protection Against Electric Shock Class I
Dimensions(mm) 460W x 584D x 355H (excluding hinge) 430W x 554D x 355H (excluding hinge)
Net Weight 41kg 39kg
Environmental Requirements Ambient temperature range:6 to 35℃, Relative humidity:not exceeding 75%RH,
Altitude: up to 2000m, Intended exclusively for use indoors,
overvoltage category:II, pollution degree:2, inclination:not exceeding 2 degrees
Accessories Included • Operator’s manual x1 • Warranty Card x1 • BART Code table x1 • Clear storage case for operator’s manual x1 • Rotor locking knob x1 • Power cord x1

* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
*The above specifications show the maximum value of speed, RCF(G) and sample capacity. These values may change according to the combination of rotor, bucket, adaptor and tubes.

See Catalog PDF for details.

* This document is created in the PDF file format.
* To view PDF files, Adobe Reader or other software is needed.
* If you don’t have Adobe Reader, click here to download its latest version.
PDF downroad LCX-200 / 100 (1.51MB)

Spin Series

Tomy
[Centrifuges] One Spin / Multi Spin

MINI PERSONAL CENTRIFUGE Wonder Spin series

One Spin

One Sping(Single Tube Spin-able Centrifuge) Spin-able with a single tube!

Features

■Quick spin-down

Can be used with a single tube!

A single microtube is able to spin without balance load. (Patent pending)

■Lid close to spin, Release hand to stop

1.Tube loading 2.Lid close(Start) 3.Release hand(Stop)

■Easy tube unloading

■Fits to universal power line

5 power plug adapters included to fit to universal power line (AC 100-240 V).
Comply with CE standards.

■Compact Design

Small foot print to save bench space.

■Spin-column or Screw capped tube available

Do not use and leave centrifuge in extremely high/low temperature and in high humidity environment because it may cause serious damage of centrifuge.

Specifications

■Single Tube Spin-able Centrifuge

Model One Spin
Max. Capacity 2.0ml × 4 microtubes
Tubes 2.0ml × 4 microtubes
1.5ml × 4 microtubes
Speed 4,000rpm (±20%)
RCF 450~1,000G (2.0ml)
420~950G (1.5ml)
Safety Devices Lid opening interlocking brake, Overcurrent fuse,
Motor overcurrent detector
(Motor lock, Unbalance)
Electric Isolation Classll
Environmental Requirements Ambient temperature range : from 5 to 35°C,
Relative humidity : 75RH or less,
Altitude : not exceeding 2000m,
For indoor use only,
overvoltage category : 11,
pollution degree : 2
Dimensions 105W × 130D × 96H mm
Net Weight 380g
Power Requirements Dedicated AC adapter
Input : 1-Phase AC100-240V 50/60Hz 0.6A
Accessories Included • AC adapter (6A-181WP05, 5 types of plugs) × 1set
• Operator’s manual × 1 copy

* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
*The above specifications show the maximum value of speed, RCF(G) and sample capacity. These values may change according to the combination of rotor, bucket, adaptor and tubes.

Multi Spin

Multi Spin(Cordless Multi-purpose Centrifuges) Changeable battery drive!

Features

■Active in anywhere at Bio-laboratory

Two way drive, AC power drive and cordless battery drive, expand usability. Flexible mobility at biosafety cabinet & clean bench use. 5 power plug adapters included to fit to world-wide universal power line (AC 100-240V). Comply with CE standards.

■Standard accessory
・AC adapter
・5 type power plug adapters

■Two rotors included to spin 2.0 ml tube and PCR strip

2.0ml × 8 tubes / 0.2ml × PCR tubes(2 strips)

■Just one push action to Close/Open

■Motor over current & Imbalance detect system

■6 minutes Timer equipped

Do not use and leave centrifuge in extremely high/low temperature and in high humidity environment because it may cause serious damage of centrifuge.

Specifications

■Cordless Multi-purpose Centrifuge

Model Multi Spin
Rotor MA-1 PA-1
Max. Capacity 2.0 ml × 8 microtubes 0.2 ml × 8 PCR tubes (2 strips)
Tubes 2.0 ml × 8 microtubes
1.5 ml × 8 microtubes
0.2 ml × 8 PCR tubes (2 strips)
Speed 6,000rpm(±20%) 6,200rpm(±20%)
RCF 1,310~2,960G (2.0 ml)
1,260~2,840G (1.5 ml)
Max. 1,200~2,690G
Min. 810~1,820G
Timer 6 minutes (Fixed)
Safety Devices Lid opening interlocking brake, Overcurrent fuse,
Motor overcurrent detector
(Motor lock, Unbalance)
Electric Isolation Classll (with AC adapter)
Environmental Requirements Ambient temperature : from 5 to 35 °C,
Relative humidity : 75%RH or less,
Altitude : not exceeding 2,000 m,
For indoor use only,
overvoltage category : II ,
pollution degree 2
Dimensions 150W × 163D × 113H mm
Net Weight 600 g (excluding rotors and batteries)
Power Requirements Dedicated AC adapter
Input : 1-Phase AC100-240V 50/60Hz 0.6A or 4×AA size alkaline battery
Accessories Included ·AC adapter (6A-181WP05, 5 types of plugs) × 1 set
·Microtubes rotor MA-1 × 1pc.
·Tube-strips rotor PA-1 × 1pc.
·Operator’s manual × 1copy

* Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.
*The above specifications show the maximum value of speed, RCF(G) and sample capacity. These values may change according to the combination of rotor, bucket, adaptor and tubes.

See Catalog PDF for details.

* This document is created in the PDF file format.
* To view PDF files, Adobe Reader or other software is needed.
* If you don’t have Adobe Reader, click here to download its latest version.
PDF downroad One Spin / Multi Spin (2.95MB)

AX Series

Tomy

We offer three high capacity general purpose centrifuges,
allowing for you to choose the best model for your spplication.

Switch to Japanese

Line UP

AXシリーズ

    • AX-521
    • AX-511
    • AX-501

Accessories here

[ECO] modo

[ECO] modo Electric power saving

Activating the power-saving [ECO] mode can also help reduce the power consumption during the waiting time (standby cooling) by allowing the temperature control bands to be changed.The chamber can cool down to the set temperature within approximately 3 minutes and a half (*) after release from ECO mode.

* Under the conditions: set temperature of 4℃ at an ambient temperature of 25℃.

 

Power consumption at ECO mode

An overall increase in cooling efficiency allows for drastic reduction in energy usage during normal operation.

  • Measurement conditions: Set to 4℃ at an ambient temperature of 25℃ while centrifugation is stopped.
    (Rotors in use: AX-521/AX-321: TS-37C+3750-TC06P)
  • The values shown above are average values obtained by measuring the units.

Flexibility

Spinning maximum 10,000rpm

All angle rotors can be spun maximum 10,000rpm

CA-16
50ml x 8
10,000rpm / 11,740G
Rotor for AX-521/511/501

Three-step acceleration and three-step and natural deceleration

Initial values for acceleration and deceleration characteristics are set from 0 to 500rpm, however, they can be varied up to maximum speed in 100rpm increments by function settings.

From micro tubes to 250ml bottles

The AX-521/511/501, with the ability to accommodate micro tubes to 250ml bottles or deep well plates, is ideal for wide range of applications. Using an optional bucket cap kit B433HS*, various types of rotors including swinging bucket rotors of biohazard-proof can be mounted.

Convenient flashing function

Convenient flashing function allows operation with preset centrifuging conditions.

*Bucket cap kit B433 is an optional kit.
HS This highly sealed rotor, which has been tested and certified by the Health Protection Agency (HPA, UK) to be compliant with the International Standard (Annex AA of the IEC 61010-2-020), meets requirements for biohazard safety. [Bucket cap kit B433] is an optional kit.

Compact Design

Compact design for minimum space requirement

コンパクト設計More compact in design, compared with existing high capacity refrigerated.centrifuge, is one of the many advantages of the AX series.
AX Series are ideally suited for applications where space is limited.

Easy to see and operate control panel

1.
Easy-to-see LCD monitor display shows various information including remaining run time, error messages, rotor types in use and records of centrifugal operation. The monitor can display in English or Japanese. (AX-521)

*Indication displays on the control panel in the photo is different from displays of actual operation.

2.
Dual color LED display allows the user to monitor the operation status just by looking the display; red indicates that the rotor is spinning while green indicates the rotor is stopped.

3.
Popular user-friendly Jog Dial equipped with an <ENTER> button on top enables setting to be changed quickly and more surely.

Safety & Ecology

Flap-drive system for safer and more efficient operation

Innovative Flap-drive system employed to maintain safe and efficient centrifugal operation allows a margin of error and eye-balancing of sample tubes.
*Some rotors are excepted.

  • Non-chlorine, ozone-friendly refrigeration medium which has zero ozone layer destruction coefficients is adopted.

One-push rotor locking knob

With a single knob push, the rotor can be quickly and securely fixed.
*Some rotors are excepted.

Flex-Spin Drive

The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.

Specifications

Model AX-521 AX-511 AX-501
Maximum Speed 10,000rpm
Maximum RCF 11,850G
Maximum Capacity 1,536ml (Deep-well plate x 8) 1,000ml (250ml x 4)
Control System Microprocessor control (feedback system)
Drive Motor Induction motor
Drive System Flex-Spin drive system (Direct drive with an automatic alignment function)
Data Entry Jog Dial equipped with an <ENTER> button
Temperature Setting Range From -9℃ to +35℃ (1℃ increment)
Speed Setting Range 100 to 10,000rpm (100rpm increments)
RCF Setting Range 10 to 11,850G (10G increments for the range less than 300G,
100G increments for the range over 300G)
Time Setting Range From 10 sec to 50 sec, in 10 sec increments, from 1 min to 99 min, in 1 min increments
or <F–> for free
Safety Devices • Imbalance detector, • Lid interlock, • Lid open/close detector, • Abnormal speed detector,
• Over-current circuit breaker, • Rotor identification system, • Motor over-current detector,
• Abnormally high or low chamber temperature detector
Additional Functions • Three-step acceleration characteristics selection, • Three memory function,
• Three-step deceleration characteristics selection, • FLASH (momentary spin) function,
• Memory function for last run parameters, • BART Code selection, • Power saving (ECO) mode
Refrigerant HFC R404A (270g) HFC R404A (260g) HFC R404A (250g)
Rated Current 120V : 12A, 220/230/240V : 6A 120V : 10A, 220/230/240V : 5A
Power Requirements 1-Phase 50/60Hz AC120V 15A, 1-Phase 50/60Hz AC220/230/240V 8A
Power Consumption(Heat output) 970W (834kcal/h) 960W (826kcal/h) 760W (654kcal/h)
Breaker Rated breaking current 120V : 15A, 220/230/240V : 7.5A
Protection Against Electric Shock Class I
Dimensions
(except protruding portion)
540W x 597D x 858H mm,
(table height; 750mm)
510W x 567D x 858H mm,
(table height; 750mm)
462W x 540D x 858H mm,
(table height; 750mm)
Net Weight 111kg (120V)
116kg (220/230/240V)
107kg (120V)
112kg (220/230/240V)
99kg (120V)
104kg (220/230/240V)
Environmental Requirements Ambient temperature range:10 to 35℃, Relative humidity:30 to 85%,
Atmospheric pressure:700 to 1,060hPa
Intended exclusively for use indoors, Overvoltage category: II, Pollution degree: 2
Accessories Included • Operator’s manual 1, • Warranty Card 1, • BART Cord table 1,
• Clear storage case for operator’s manual 1, • Attaching screw for clear storage case 1,
• Power cord×1pc., • Spanner 1, • Level gauge 1, • Rotor locking knob 1, • Drain plug 1

※Specifications and design are subject to change for improvement without prior notice. Please ask for the latest specifications prior to your order and procurement.

 

 

LMC-4200R

Biosan

1

Description

Laboratory bench-top centrifuge with refrigeration LMC-4200R provides temperature control of biomaterial during centrifugation. Temperature control of the so-called “cold-shelf” is a gold standard for enzymologists and cell biologists because it ensures conditions necessary for reproducibility of the sample preparation stage. Temperature control absence at this stage can cause unpredictable results.

LMC-4200R is a modern centrifuge designed for operation with microtest plates and tubes from 10 to 50 ml.

Features:

  • Effective way of acceleration and deceleration:
    Run-up time 15 sec;
    Run-down time, not more 30 sec;
  • Efficient rate of chamber refrigeration: under 10 min;
  • Maintenance of stable temperature during operation;
  • User-friendly setting of centrifugation parameters (speed, temperature, time) and simultaneous display of both set and actual values;
  • Safe operation is provided by a metal protection chamber and a case cover, automatic stop at imbalance (emergency shutdown,  “IMBALANCE” displayed) and a lock keeping the lid closed while the centrifuge is running.
  • Low noise level;
  • Wide choice of accessory rotors.

1


Specification

Termperature control range
–10°C … +25°C
Stable temperature maintenance range
25°C below ambient … to +25°C
Temperature setting resolution
1°C
Speed regulation range for centrifuge tubes
100–4,200 rpm
(3,370 × g)
Speed regulation range for microtitre plates
100–2,000 rpm
(560 × g)
Speed setting resolution
100 rpm
Rotor imbalance diagnostics (automatic stop, “IMBALANCE” warning)
+
Slowdown time, not more
30 sec
Display
LCD, 2 lines
Digital time setting
1–90 min (increment 1 min)
Chamber diameter
335 mm
Dimensions
635x580x335 mm
Weight
56 kg
Nominal operating voltage
230 V, 50 Hz
Power consumption (230 V)
990 W (4.3 A)

 

MX Series

Tomymx-series up to approximately 43% (※) reduction in electric power consumption during the waiting time.

※ The figure mentioned above is calculated by comparing MX-305 and MX-307. The reduction rates of power consumption vary from model to model and may vary from one product to another.

Basic power saving

TOMY’s MX-Series centrifuge has achieved an up to approximately 15%(※) reduction in electric power consumption compared to the former model (MX-**5 Series) by controlling the motor fan drive during the waiting time (standby cooling).

※ The figure mentioned above is calculated by comparing MX-105 and MX-107. The reduction rates of power consumption vary from model to model and may vary from one product to another.

Switch-on ECO mode to save the power consumption [Patent pending]

Activating the power-saving [ECO] mode can also help reduce the power consumption during the waiting time (standby cooling) by allowing the temperature fluctuation bands to be changed. The chamber can cool down to the set temperature(※) within approximately three minutes after release from ECO mode.

※ Under the conditions: set temperature of 4℃ at an ambient temperature of

3

Comparison of power consumption between MX-**5 Series and MX-**7 Series in the ECO mode

4

■Measurement conditions:Set to 4℃ at an ambient temperature of 25℃ while centrifugation is stopped.(Rotors in use: MX-30*:TMA-300+AR015-24×3  MX-20*:TMA-200+AR015-24×2 MX-10*:TMA-100+AR015-24)
■The values shown above average values obtained by measuring the units.

Product features

MX-307

Flagship of the MX-Series, capable of accepting 50ml conical tubes

5AR510-04 6PCR96-02

  • Accommodates all TOMY Rack-in-Rotors ; TMA-100/200/300
  • Stack up to three racks high, total 2ml x 72 can be processed.
  • Accommodates a high g-force centrifugation rack ; AR510-04
  • Accommodates a rack for up to 96-well PCR plate X 2 ; PCR96-02
  • Provides large capacity performance in the same compact design applied to other models of the MX-Series

MX-207

From 2ml micro tubes to 30ml tubes, the MX-207 supports a wide range of applications.

7AR050-12 85ml Conical tube (Right; 1.5ml microtu)be

  • Accommodates two models of TOMY Rack-in-Rotors ; TMA-100/200
  • Stack up to two racks high, total 2ml x 48 can be processed.
  • A well balanced unit combining high speed centrifugation and large sample capacity
  • Accommodates a rotor rack for up to 5ml x 12 ; AR050-12

MX-107

Advanced centrifuge model with simple operation designed to spin micro tubes

  • Accommodates a TOMY Rack-in-Rotor TMA-100 compatible with four types of racks
  • Supports from 8-Strip PCR tubes to 2ml x 24 micro tubes
  • Provides up to 15,000rpm high speed centrifugation
  • All MX-107 compatible rotors can reach their maximum speed within 10 seconds.

Sample animated images

Sample animated images of the “3D High Speed Oscillating movement” can be viewed by pressing the “STOP” button/”STERT” button.

Rack in Rotor

9

TOMY “Rack-in-Rotor ”
-The Future of Centrifuge Rotor System

One of the most innovative features of the TOMY MX-Series High Speed Refrigerated Micro Centrifuge is its unique “Rack-in- Rotor” system using a combination of carbon fiber rotors and a variety of drop-in racks made of resin for greater convenience, higher performance and lower cost, including:

1. Stackable, drop-in/lift-out rotor racks for easy placement and removal
Lightweight resin racks have a drop-in/lift-out design which allows for easy placement and replacement of tubes. These rotor racks are available in a wide variety of types, and can be stacked in layers to suit your application.

2. Lightweight, yet stable rotation, and excellent acceleration/deceleration performance
Each rack has four slits so that the adhesion of the rack to the inner wall of the rotor is facilitated by centrifugal force, providing stable operation of the rotor. Lightweight rotors and racks can also increase acceleration and deceleration performance.

3. A wide variety of racks available at affordable prices
A large selection of resin racks is provided at affordable prices to accommodate tubes and plates of different volumes and numbers, which supports a diverse array of sample processing applications.

4. A portable rack for sample tubes
A resin rack can be used for a wide range of purposes, including storage and transportation. It can be used as a tube stand or carrier to hold or transport sample tubes.

MX – Series

HIGH SPEED REFRIGERATED MICRO CENTRIFUGE
TOMY “MX-Series ”
-Toward High Performance and Simplicity!

The MX-Series is a high speed refrigerated micro centrifuge that is designed for high performance and simplicity of operation.

1. Powerful motor and inverter realize fast acceleration and deceleration.

2. All models are equipped with an imbalance detection system as a standard safety function.

3. User friendly, beautiful and functional design with human factors engineering in mind

4. Compact body with wheel design for easy installation and transportation

Easy-to-see, easy-to-use control panel

  • User friendly center Jog Dial operation
  • Highly visible dual color LED display for operating status indication
  • Memory function storing up to two sets of operating parameters for more efficient centrifugation
  • One touch key operation permits easy acceleration of the rotor to a maximum speed for the centrifugation protocol selected.
  • 1 – 99 minutes timer with 1 minute increment

10


Specifications

Models

MX-307

MX-207

MX-107

Maximum Speed

16,000rpm

15,000rpm

Maximum RCF

21,130G

21,130G

20,380G

Maximum Capacity

50ml x 4

30ml x 6

2ml x 24

Control System

Microprocessor control (feedback system)

Drive Motor

Induction motor

Drive System

Direct drive with an automatic alignment function

Data Entry Device

Jog Dial

Temperature Setting Range

– 9 to 35°C (1°C increment)

Speed Setting Range

300rpm to Maximum speed (100rpm increments)

RCF Setting Range

100G to Maximum RCF (100G increments)

Time Setting Range

0 to 99 minutes (1minute increment) or <F–> for free

Additional Functions

• FLASH (momentary spin) function, • Memory function(two sets), • Previous setting memory, • Soft Brake function

Safety Devices

• Lid interlock, • Lid open/close detector, • Over-speed detector, • Over-current circuit breaker, • Motor over-current detector, • Abnormally high or low chamber temperature detector, • Rotor identification system, • Imbalance detector

Refrigerant

HFC134a(240g)

HFC134a(210g)

HFC134a(200g)

Power Requirements

Single phase AC110/120V 50/60Hz, 15A
Single phase AC220/230/240V 50/60Hz, 8A

Power Consumption
(calorific value)

860 W(740kcal/h)

790 W(680kcal/h)

650 W(560kcal/h)

Dimensions (except protrusion)

345W x 465D x 860H mm(table height:755Hmm, lid in open position:1125Hmm )

Net Weight

66kg(110/120V), 71kg(220/230/240V)

Cord Length

3m

Environmental
Requirements

Ambient temperature range:10 to 35°C, Relative humidity:30 to 85%,
Atmospheric pressure:700 to 1060hPa

Accessories Included

• Operator’s manual 1, • Warranty card 1, • Customer card 1, • Inspection sheet 1, • Hexagon wrench 1, • Clear storage case 1, • Attaching screw 1, • Caster holder 2, • Drain plug 1

 

 

KITMAN-T24

Tomy
1


2Equipped with a newly developed “W-Memory Program” , the KITMAN is a highly reliable workhorse in biological research laboratories.

TOMY’s newest high speed refrigerated micro centrifuge, the “KITMAN” is equipped with a unique program operation function for a continuous run of any two memories coupled in series.This function meets the requirements of various sample protocols, including DNA/RNA extraction and purification, and offers increased efficiency and validity in complicated centrifuge operation. This centrifuge also features a long established easy-to-use design with versatile, advanced functions, plus energy-saving mode, all in a compact body.Designed with the needs of biotechnology researchers in mind, the “KITMAN” is a new reliable laboratory workhorse.

Product features

Various program operations & multi-memory function

  • In addition to a multi-memory function that allows recall of up to 6 sets of operating conditions at one touch of a button, the “KITMAN” also provides a newly developed program operation function, with which two memories are coupled in series to achieve a continuous run operation. This function enables any combinations of three program patterns to be operated in a single protocol, and supports a wide variety of kits and protocols for DNA/RNA extraction and purification that require 2ml micro tubes.
  • The reaction time of reagents can also be programmed, which allows the operator to make good use of the time for the reaction to be completed, as well as eliminates the operator’s failure to remember the timing. This will enhance the efficiency and validity of the laboratory work.

3

*Indication displays on the control panel in the photo is different from displays of actual operation.

Easy-To-See LED Display

The control panel features easy-to-see LED display that allows the operator to easily confirm a set temperature, speed and time at a glance.

4Program indicator lamp flashes during program operation.

 

5The display indicates “Pr.” by a green light while the PRE-TEMP function is in operation.

 

Speed is indicated by a red light while the rotor is spinning, and by a green light while stopped.
6

*Indication displays on the control panel in the photo is different from displays of actual operation.

Convenient Function Keys

Function keys allow settings to be changed or modified to suit specific requirements.

  • Acceleration/deceleration characteristics preset speed setting
  • “FLASH” (momentary spin) function setting (mode and speed)
  • Buzzer setting (type and time)
  • Lid-up monitoring time setting
  • Power saving mode setting

Two-Mode “FLASH” Function

“FLASH” or a quick run function for momentary spin provides the following two modes:

  1. Short-term operation of the centrifuge will continue at set speed as long as the “FLASH” key remains pressed.
  2. With one push of the key the rotor begins to accelerate and will start deceleration when it reaches set speed.

Power Saving Mode

7When operation standby status continues for a long time, the power saving mode becomes active and stops the fan and refrigerator. During the power saving mode, the panel display indicates “oFF”. The idle time before the power saving mode is entered can be set between 1 and 12 hours. (The default time is 4 hours.)

PRE-TEMP Function

With the PRE-TEMP function air inside the chamber is stirred by spinning the rotor, which allows the rotor to reach set temperature quickly. It takes approximately 5 minutes to reach the set temperature of 4°C from the ambient temperature of 25°C. The result is an optimal function that supports temperature-sensitive samples. When the temperature inside the chamber increases in the power saving mode, the function can also cool the chamber effectively, saving time and energy.

Easy-To-Install Compact Design


8Its compact body with a width of 29cm takes up very little lab space.

High Grade, Affordable Centrifuge

Equipped with upgraded functions, the TOMY “KITMAN” delivers higher performance at an affordable price.

Rotor


9Sold with KITMAN-T24 / TMP-2 (24 x 2ml).


Specifications

Model

KITMAN-T24

Compatible Rotor

TMP-2

Maximum Speed

13,500rpm

Maximum RCF

17,730G

Maximum Capacity

2ml x 24

Drive Motor

Induction motor

Temperature Setting Range

– 9 to 35℃ (1°C increments)

Speed Setting Range

0rpm or 300 to 13,500rpm (in 100rpm increments)

Time Setting

10 to 50 seconds (in 10 second increments), 1 to 99 minutes (in 1 minute increments), <F−> free

Safety Devices

• Lid interlock, • Abnormal speed detector, • Lid open/close detector, • Imbalance detector, • Motor over-current detector, • Over-current circuit breaker (also used as power switch), • Abnormally high or low chamber temperature detector

Refrigerant

HFC-134a (135g)

Rated Voltage

AC120V, 60Hz

AC220V, 50Hz

AC220V, 60Hz

AC230V, 50Hz

AC240V, 50Hz

Power Input

5A

3A

Power Consumption
(Calorific Value)

400W(344kcal/h)

Dimensions W x D x H (mm)
(except for the protruding portion)

290 x 515 x 295 (table height ; 260mm, height with open lid ; 565mm)

Net Weight

37kg

 

CAX-371

Tomy

1

 HYBRID REFRIGERATED CENTRIFUGE

All in one unit from micro tube rotors to multi-place swing rotors.
A reliable trump card for centrifuge operations.
The CAX-371, a high-performance refrigerated centrifuge that combines functions of high speed micro centrifuge and versatile low speed centrifuge into one compact model, meets a wide range of applications.

*1 In case of CAX-371. The reduction rates of power consumption vary from model to model and may vary from one product to another.

 2Activating the power-saving [ECO] mode can also help reduce the power consumption during the waiting time (standby cooling) by allowing the temperature control bands to be changed.The chamber can cool down to the set temperature within approximately 3 minutes (*2) after release from ECO mode.

*2 Under the conditions: set temperature of 4℃ at an ambient temperature of 25℃.

Power consumption at ECO mode

3

  • Measurement conditions: Set to 4℃ at an ambient temperature of 25℃ while centrifugation is stopped.
    (Rotors in use: CAX-371: TS-7C+7215-06)
  • The values shown above are average values obtained by measuring the units.

Flexibility

Three-step acceleration and three-step and natural deceleration

4

Initial values for acceleration and deceleration characteristics are set from 0 to 500rpm, however, they can be varied up to maximum speed in 100rpm increments by function settings.

From micro tubes to 250ml bottles

The CAX-371, with the ability to accommodate micro tubes to 250ml bottles or deep well plates, is ideal for wide range of applications. Using an optional bucket cap kit B43311*, various types of rotors including swinging bucket rotors of biohazard-proof can be mounted.

Convenient flashing function

Convenient flashing function allows operation with preset centrifuging conditions.

*Bucket cap kit B433 is an optional kit.
11 This highly sealed rotor, which has been tested and certified by the Health Protection Agency (HPA, UK) to be compliant with the International Standard (Annex AA of the IEC 61010-2-020), meets requirements for biohazard safety. [Bucket cap kit B433] is an optional kit.

Compact Design

Compact design for minimum space requirement

5

 

With its compact design of 462mm width and 559mm depth it is ideally suited to applications where space is limited.

Easy to see and operate control panel

6

asy-to-see LCD monitor display shows various information including remaining run time, error messages, rotor types in use and records of centrifugal operation. The monitor can display in English or Japanese.

7*Indication displays on the control panel in the photo is different from displays of actual operation.
Dual color LED display allows the user to monitor the operation status just by looking the display; red indicates that the rotor is spinning while green indicates the rotor is stopped.

8

9Popular user-friendly Jog Dial equipped with an <ENTER> button on top enables setting to be changed quickly and more surely.

Safety & Ecology

Flap-drive system for safer and more efficient operation

1

Innovative Flap-drive system employed to maintain safe and efficient centrifugal operation allows a margin of error and eye-balancing of sample tubes.
*Some rotors are excepted.

  • The CAX-371 is equipped with a function to automatically reduce the rotation speed and shut the system down if it is being run over the imbalance tolerance limit.
  • Non-chlorine, ozone-friendly refrigeration medium which has zero ozone layer destruction coefficients is adopted.

One-push rotor locking knob

With a single knob push, the rotor can be quickly and securely fixed.
*Some rotors are excepted.

Flex-Spin Drive

The Flex-Spin Drive features a flexible motor shaft that equalizes minor imbalances without damaging the centrifuge or triggering the imbalance protection system. This allows excellent tolerance for minor differences in sample volumes.


Specifications

Model

CAX-371

Maximum Speed

15,000rpm

Maximum RCF

21,130G

Maximum Capacity

1,000ml (250ml x 4)

Control System

Microprocessor control (feedback system)

Drive Motor

Induction motor

Drive System

Flex-Spin drive system (Direct drive with an automatic alignment function)

Data Entry

Jog Dial

Temperature Setting Range

From -9℃ to +35℃ (1℃ increments)

Speed Setting Range

100 to 15,000rpm (100rpm increments)

RCF Setting Range

10 to 21,130G
(10G increments for the range less than 300G,100G increments for the range over 300G)

Time Setting Range

From 10 sec to 50 sec, in 10 sec increments, from 1 min to 99 min, in 1 min increment
or <F–> for free

Safety Devices

• Imbalance detector, • Lid interlock, • Lid open/close detector, • Abnormal speed detector,
• Over-current circuit breaker, • Rotor identification system, • Motor over-current detector,
• Abnormally high or low chamber temperature detector.

Additional Functions

• Three-step acceleration characteristics selection, • Three memory function,
• Three-step deceleration characteristics selection, • FLASH (momentary spin) function,
• BART Code selection, • Power saving (ECO) mode.

Refrigerant

HFC134a (280g)

Rated Voltage

AC120V, AC220/230/240V

Rated Current

120V : 12A, 220/230/240V : 6A

Power Requirements

Single phase 50/60Hz, AC120V 15A, AC220/230/240V 8A

Power Consumption(Heat output)

1,040W (900kcal/h)

Breaker

Rated breaking current 120V : 15A, 220/230/240V : 7.5A

Protection Against Electric Shock

Class I

Dimensions
(except protruding portion)

462W x 559D x 939H mm, (table height; 776mm)

Net Weight

118kg (120V) 123kg (220/230/240V)

Environmental Requirements

Ambient temperature range:10 to 35℃, Relative humidity:30 to 85%,
Atmospheric pressure:700 to 1,060hPa

Accessories Included

• Operator’s manual 1, • Warranty Card 1, • BART Cord table 1,
• Clear storage case for operator’s manual 1, • Attaching screw for clear storage case 1,
• Spanne 1, • Leveler 1, • Rotor locking knob 1, • Drain plug 1

 

Microspin 12

Tomy

Description

High-speed mini-centrifuge Microspin 12 is a compact desktop centrifuge designed for biomedical laboratories.

Microspin 12 is used for extracting RNA/DNA samples, sedimentation of biological components, biochemical and chemical analysis of microsamples.

A display simultaneously shows actual and set values for:

  1. Centrifugation time;
  2. Set and actual speed values;
  3. Relative centrifugal force.

A brushless rotor provides noiseless performance at the maximal speed and long service life. An angular rotor is designed for  accommodation of 12 Eppendorf microtubes. The rotor is made of aluminium, it is equipped with fixing lid and included in the standard specification of the centrifuge. Constant airflow around the rotor reduces risk of samples overheating during operation.

123

Metal protective inserts inside the casing and lid, automatic imbalance switch-off and locking of a lid provide safe operation. Completion of centrifugation is indicated by a sound signal.

The external power supply unit allows operation of Microspin 12 in cold rooms (at ambient temperatures from +4°C to +25°C).

Standard set:

Built-in rotor MSR-12 with protection lid
12 places for microtubes 1.5/2 ml
A-02 adapter    12 pieces for microtubes 0.2 ml
A-05 adapter    12 pieces for microtubes 0.5 ml

 


Specification

Speed control range
1000 – 14500 rpm (increment 100 rpm)
Relative centrifugal force control range
50–12,400 × g
Digital time setting
1–30 min (increment 1 min)
Acceleration time up to 14,500 rpm
20 sec
Slowdown time, not more
10 sec
Display
LCD, 2 line
Safety: Rotor imbalance diagnostics: automatic stop, “IMBALANCE” warning
+
Overall dimensions
200x240x125 mm
Weight
3.5 kg
Input current/power consumption
24 V, 2.5 A / 60 W
External power supply
Input AC 100–240 V 50/60 Hz, Output DC 24 V