UV Cabinet

UV Cabinet

Biosan

UVC/T-AR, DNA/RNA UV-cleaner box

1

Description

DNA/RNA UV-cleaner box UVC/T-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, plexiglas walls and working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

2

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Plexiglas: Polymethyl methacrylate ALTUGLAS EX

Working surface material

Steel with chemicals resistant powder coating

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

Radiation type

UV (λ = 253.7 nm), ozone-free

UV radiation level

15 mW / cm2 / sec

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

8 mm

Optical transmission

92%

UV protection

>99.90% Polymethyl methacrylate ALTUGLAS EX

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

Inlet for power cords

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 535 × 555 mm

Weight (net / gross)

23 / 33 kg

Optional table

T-4 (800 × 600 × 750 mm)

UVC/T-M-AR, DNA/RNA UV-cleaner box

3

Description

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

4 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

Inlet for power cords or optional 1x Built-in socket

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 535 × 555 mm

Optional table

T-4 (800 × 600 × 750 mm)

Weight (net / gross)

31 / 39 kg

UVT-B-AR, DNA/RNA UV-cleaner box

4

Description

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

5

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

2 mm

Thickness of upper front panel

8 mm

Thickness of screen

4 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

1 Built-in socket, max. 1000 W or optional inlet for power cords

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 585 × 555 mm

Optional table

T-4 (800 × 600 × 750 mm)

Weight (net / gross)

32 / 42 kg

UVT-S-AR, DNA/RNA UV-cleaner box

6

Description

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

7

Specially assigned moving tables T-4L (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

2x30W built‑in bactericidal, TUV30WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1 х 30W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-30W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

5 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

1200 × 520 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

3 Built-in sockets max. 1000 W

Nominal operating voltage

230 V, 50 Hz or 120 V, 60 Hz

Power consumption (230V / 120 V)

315 VA (1.4 A) / 530 VA (4.5 A)

Overall dimensions

1245 × 585 × 585 mm

Weight (net / gross)

58 / 68.5 kg

Optional table

T-4L (1290 × 600 × 770 mm)

Optional drawer unit

LF-1 (300 × 450 × 705 mm)


UVC/T-M-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV–cleaner box provide protection against contamination.

Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the box during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cleaner box during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal, TUV25WG13 UV-C
UV radiation level 15 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 4 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 650 × 475 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords or optional 1x Built-in socket, max. 1000 W (pls, order respectively)
Nominal operating voltage 100-240 V, 50/60Hz
Power consumption 67 W
Overall dimensions (W×D×H) 690 × 535 × 555 mm
Weight (net / gross) 28.8 / 39 kg
Optional table T-4 (800 × 600 × 750 mm)

UVT-B-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV–cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal, TUV25WG13 UV-C
UV radiation level 15 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 2 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 650 × 475 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords or optional 1x Built-in socket, max. 1000 W (pls, order respectively)
Nominal operating voltage 100-240 V, 50/60Hz
Power consumption 67 W
Overall dimensions (W×D×H) 690 × 585 × 555 mm
Optional table T-4 (800 × 600 × 750 mm)
Weight (net / gross) 31.2 / 42 kg

UVT-S-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the box during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4L (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV – cleaner box during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 2x30W built‑in bactericidal, TUV30WG13 UV-C
UV radiation level 15 mW / cm2 / s
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1 х 30W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-30W
Thickness of side panels 4 mm
Thickness of upper front panel 8 mm
Thickness of screen 5 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 1200 × 520 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit 3 Built-in sockets max. 1000 W
Nominal operating voltage 230 V, 50 Hz or 120 V, 60 Hz
Power consumption (230V / 120 V) 315 VA (1.4 A) / 530 VA (4.5 A)
Overall dimensions (W×D×H) 1245 × 585 × 585 mm
Weight (net / gross) 58 / 68.5 kg
Optional table T-4L (1290 × 600 × 770 mm)
Optional drawer unit LF-1 (300 × 450 × 705 mm)
Personal Vortex

Personal Vortex

BiosanV-1 plus, Personal Vortex for tubes

1

Description

Vortex V-1 plus is an ideal instrument for gentle mixing to vigorous resuspension of cells and biological and chemical liquid components in tubes using eccentric mechanism.

Vortex has two modes:

  1. Continuous operation;
  2. Impulse operation (activated by pressing the cap with the tube’s bottom).

 Specification

Eccentric mixing principle +
Speed control range 750-3000 RPM
Mixing module for tubes from 1.5 to 50 ml
Maximum mixing volume 30 ml
Orbit 4 mm
Overall dimensions 90x150x80 mm
Weight 0.8 kg
Input current/power consumption 12 V, 320 mA / 3.8 W
External power supply Input AC 100–240 V; 50/60 Hz; Output DC 12 V

Separatory Funnel Shaker

Jisico

Separatory funnel shaker

Separatory funnel shaker

Model : J-MSFS

● Digital timer with digital display: time can be set up to 99 minutes or continuous operation.

● Adopting brushless motor, minimum noise and vibration is ensured and is capable of heavy duty jobs.

● Capable of operating at high speed of max 350 rpm by adopting robust structure.

● With adjustable funnel holders, 250ml~1,000ml funnels can be used.

● Can be used as horizontal reciprocating shaker utilizing flask clamps. (option)

012-05-2-450s.jpg012-05-4-450s.jpg

J-MSFS-003-300.jpg

J-MSFS

 

UV Cleaner-Recirculator

Biosan

UVR-M, UV Cleaner–Recirculator

uvr-m-chart2

Description

UVR-M is applicable for UV air inactivation in research laboratory rooms, waiting rooms in outpatients departments, surgeries and veterinary stations.

The devices provide complete protection from direct ultraviolet radiation.

Recirculators fixation:

  • Convenient fixation on walls (standard)
  • Mounting on a movable tripod (optional)

Specification

UV radiation source: 1 lamp – 25W Bactericidal, TUV25WG13 UV-C
UV radiation level 18 mW / cm2 / sec
Air-flow productivity 14 m3/hour
Full user protection from direct UV light +
UV lamp operation indicator +
Overall dimensions (W×D×H) 110x135x660 mm
Weight 3.4 kg
Nominal operating voltage 230 V, 50 Hz or 120 V, 60 Hz
Power consumption (230V / 120 V) 125 VA (540 mA) / 160 VA (1.3 A)

UVR-Mi, UV Cleaner–Recirculator

uvr-m-chart2-1

Description

UVR-Mi is applicable for UV air inactivation in research laboratory rooms, waiting rooms in outpatients departments, surgeries and veterinary stations.

The devices provide complete protection from direct ultraviolet radiation.

Advantages of UVR-Mi:

  • UVR-Mi is the more powerful model of UV air flow cleaner with two UV-lamps
  • Full user protection from direct UV radiation;
  • Two operation modes — short time (under timer control) and continuous operation;
  • Indication of UV lamps working hours.

Recirculators fixation:

  • Convenient fixation on walls (standard)
  • Mounting on a movable tripod (optional)

Specification

UV radiation source: 2 lamps – 25W Bactericidal, TUV25WG13 UV-C
UV radiation level 36 mW / cm2 / s
Air-flow productivity 14 m3/hour
Full user protection from direct UV light +
Display LCD
UV lamp operation indicator +
UV lamp lifetime counter +
Timer 1 min–24 hrs / non–stop
Automatic switch ON/OFF +
Lamp fault detection +
Overall dimensions (W×D×H) 110x135x660 mm
Weight 3.4 kg
Nominal operating voltage 230 V, 50 Hz
Power consumption (230V / 120 V) 110 W (0.5 A)

Electric Muffle

J-FM28, J-FM38, J-FM48

1

● With heating elements at four sides of inner wall, heating is instantly achieved at uniform level.
● Heating elements is installed in the walls, which prevents generation of corrosive gas and contacts with water vapor, to ensure longer life.
● Microprocessor PID auto-tuning controller with digital setting and display.
● Since the air circulates between twin-fold wall structure, this air circulating system cools temperature of outer case.
● Heating cabinet is separated from control box by heat resistant panel to protect the electronic controller.

Model

J-FM28

J-FM38

J-FM48

Overall size (W×D×H)

mm

415/435×555/610×560/575

560/580×600/655×680/695

1,010×770×1,220

Chamber size (W×D×H)

mm

150×300×100

250×350×160

350×450×400

Capacity

4.5

14

63

Temperature

range

Ambient+10 ~ 1,000(Max.)

using range

300 ~ 900

accuracy

±1% on setting temp.

controller

PID controller

regulator

SSR type

SCR type

Thermocouple

K type(CA)

Heater

kW

3

4.5

12

Heating-up time

Reaches 600 within 50min. (J-FM28)

Insulation

Fiber & ceramic

Heating element

Molded Kanthal A1

Safety device

Self diagnosis function (Temp. overheating,
SSR short circuit, sensor short circuit), ELB.

Material

interior

Molded ceramic block

exterior

Steel plate with powder coated finish

Power source & consumption

AC 230V 50/60Hz 1phase

AC 230V 50/60Hz 3phase

Net weight

kg

48

82

 –

Water Distilling Apparatus

J-WD, J-WD-1, J-WD-2

1

● Interior and exterior made of anti-corrosive stainless steel.
● With water leveler installed, it automatically cuts off power supply to stop operation when water level is low.
● Removable cover for easy cleaning, stable performance and easy maintenance.

Model

J-WD

J-WD-1

J-WD-2

Environmental temp. range

5 ~ 40

Approx. size (W×D×H)

mm

660 × 400 × 680

660 × 400 × 800

660 × 400 × 800

Heater(sheath)

W

3,000

6,000

9,000

Capacity

/hr

4

8

12

Material body

All stainless steel plate

Power source & consumption

AC 220V 60Hz 1phase
13.6A

AC 220V 60Hz 1phase
27.3A

AC 220V 60Hz 1phase
40.9A

Net weight

kg

6.5

11.7

14.0

J-WDR

2

● Designed to distill the primary distilled water to get highly pure distilled water.
● Interior and exterior made of anti-corrosive stainless steel.
● With water leveler installed, it automatically cuts off power supply to stop operation when water level is low.
● Removable cover for easy cleaning, stable performance and easy maintenance.

Model

J-WDR

Environmental temp. range

5 ~ 40

Heater(sheath)

W

3,000×2ea

Capacity

/hr

4

Material

body

All stainless steel plate

frame

Steel pipe with powder coated finish

bottle

PE bottle(10)

Power source & consumption

AC 230V 50/60Hz 1phase

Multi Vortex

Biosan

 V-32, Multi-Vortex for tubes

2

Description

Multi-Vortex V-32 is intended for intensive stirring of bacterial and yeast cell, washing from the culture medium and extraction of metabolites and enzymes from cells and cell cultures.

It is different from V-1 by the possibility of mixing up to 32 tubes simultaneously.

Vortex is applicable for:

  • Performing various DNA operations — deproteinisation of DNA/ protein complexes;
  • Purification of low-molecular DNA/RNA fragments in PCR-diagnostic.

Multi-Vortex has two operation modes:

  1. Continuous operation;
  2. Impulse operation.

3

V-32 is supplied with a 32-socket universal platform for Eppendorf type tubes up to 1.5 ml (1.5/0.5/0.2 ml — 16/8/8 sockets) PV-32 and PL-1 platform for mixing single tube up to 15 ml.

An optional 6-socket platform PV-6/10 for 10 ml tubes (max. tube diameter 15 mm) can be supplied on request.

 Specification

Speed control range 500-3000 rpm
Acceleration time 3 sec
Orbit 2 mm
Continuous / impulse operation +
Maximum load 70 gr
Maximum continuous operation time 8 hrs
Dimensions 120x180x100 mm
Weight 1.5 kg
Input current/power consumption 12 V, 320 mA / 3.8 W
External power supply Input AC 100–240 V; 50/60 Hz; Output DC 12 V

MSV-3500, Multi Speed Vortex

4

Description

Multi Speed Vortex MSV-3500 is designed for soft or intensive mixing of reagents in different size and type plastic tubes.

It is designed for operation in life science laboratories working in the fields of biochemistry, cell and molecular biology.

Unit has four types of interchangeable platforms: for Eppendorf type microtest tubes, 10/15/50 ml tubes (diameter 12/16/30 mm). Platforms can be ordered separately or as one set with MSV-3500.

Speed and time are under microprocessor control. LCD display indicates two lines of values: the set and actual values of speed and time.

Unit provides high maximum speed of platform rotation efficiently mixing microvolumes (less than 5 μl) of samples.

Specification

Speed control range 300–3,500* rpm
* Maximum speed depends on load
Digital time setting 0–60 min / non-stop
Display LCD, 2 x 16 signs
Acceleration time 3 sec
Orbit 4 mm
Maximum load 0.2 kg
Maximum continuous operation time 8 hrs
Dimensions 180x170x145 mm
Weight 2.6 kg
Input current/power consumption 12 V, 1 A / 12 W
External power supply Input AC 100–240 V; 50/60 Hz; Output DC 12 V

Tube Mixer

Tomy

Variable speed settings

Mixing speed can be variable from gentle shaking to powerful mixing with visually checking the sample in the tube.

Eccentric oscillation method

Unique mixing method provides consistent uniform mixing action and ensures highly efficient mixing performance.

Compact body

Compact and slim body design with its dimensions of 300W × 135D × 150H mm allows MT-400 to be placed even inside the incubator.

Detachable tube rack

MT-400 Microtube Mixer

 

1

The detachable tube rack is easily dismounted for carrying test tubes and can also serve as a tube stand.
2

Main applications

  • ・Mixing of cell suspensions
  • ・Mixing of the reagents of an assay
  • ・Uniform triturating of samples
  • ・Other general mixing works

Optional accessories

3

5ml Tube Rack(TR4005)

Optional TR4005 rack allows up to 5 ml x 12 tubes to be stirred.

4

Tube Rack Cover(TC4000)

Keeps the tube in the rack without jumping out even powerful mixing.

Specifications

 

Model

MT-400

Mixing method

Eccentric oscillation method

Mixing capacity

1.5 ml × 40 tubes (with supplied rack: TR4002)
5 ml × 12 tubes (with optional rack: TR4005)

Tube rack

Detachable

Power requiremen

100 – 240V AC (50 / 60Hz) 0.3A

Dimensions

300W×135D×150Hmm (excluding protruding portions)

Net weight

3.2kg

Rockers

BiosanMR-1, Mini-Rocker Shaker

1

Description

Mini Rocker–Shaker MR-1 shaker has been upgraded to provide reliable continuous operation and smooth platform
motion at lower speed. Non–stop mode up to 7 days and over 2 years of trouble–free operation are guaranteed due to direct drive mechanism and brushless motor.

MR-1 provides regulated gentle rocking motion of the platform and mixing of liquid components.

It is a compact, noiseless device designed for personal use.

Ideal for minigel destaining after electrophoresis, conducting reactions of Northern, Southern and Western
blots.

Non–slip rubber mat located on the shaker’s platform provides stable position for vessels during shaking.

MR-1 can be used in cold rooms or incubators, operating at ambient temperature range +4°C to +40°C. Low voltage
external power supply (12 V) provides electrical safety in humid environment.

Optional dimpled mat PDM prevents different size tubes from rolling around the platform

Specification

Mixing frequency range

5–30 oscil/min

Fixed tilt angle

Maximum continuous operation time

168 h

Direct drive mechanism

+

Digital time setting

1 min-24 hrs / non-stop

Non-slip rubber mat is supplied as standard

+

Maximum load

0.5 kg

Display

LED

Platform working area

200×200 mm

Overall dimensions

220x205x120 mm

Weight

2.1 kg

Input current/power consumption

12 V, 320 mA / 3.8 W

External power supply

Input AC 100–240 V; 50/60 Hz; Output DC 12 V

Warranted service life

24 months

MR-12, Rocker-Shaker

2

Description

MR-12 Rocker–Shaker provides both soft and intensive mixing of solutions or nutrient media in vessels or plastic bags placed on the platform. Adjustable speed and platform tilt angle allows setting parameters for optimal solution transfer and mixing.

The device is ideal for gel destaining after electrophoresis and homogenisation of bioextraction media. It is optimal for biomolecule hybridization on strips and for staining/destaining procedures. When installed inside a bioincubator it is ideal for growing cells and cell cultures in disposable plastic reactor-bags (working volumes up to 10 liters, media volumes up to 5 liters).

Rocker–Shaker can be used in cold rooms or incubators, operating at ambient temperature range +4°C to +40°C. Low voltage external power supply (12 V) provides electrical safety in humid environment.

 

Specification

Mixing frequency range

1–99 oscill/min (increment 1 oscill/min)

Tilt angle range (for 1–50 oscill/min)

0°–10° (increment 1°)

Fixed tilt angle (for 51–99 oscill/min)

10°

Digital time setting

1 min–99 hrs 59 min (increment 1 min) / non-stop

Display

LCD, 16 x 2 signs

Maximum continuous operation time

168 hrs

Maximum load

5 kg

Platform with non-slip rubber mat is included in standard set

+

Platform working area

480 x 380 mm

Overall dimensions

400 x 480 x 250 mm

Weight

11.6 kg

Input current/power consumption

12 V, 1.1 A / 13 W

External power supply

Input AC 100–240 V 50/60 Hz; Output DC 12 V