UV Cabinet

UV Cabinet

Biosan

UVC/T-AR, DNA/RNA UV-cleaner box

1

Description

DNA/RNA UV-cleaner box UVC/T-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, plexiglas walls and working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

2

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Plexiglas: Polymethyl methacrylate ALTUGLAS EX

Working surface material

Steel with chemicals resistant powder coating

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

Radiation type

UV (λ = 253.7 nm), ozone-free

UV radiation level

15 mW / cm2 / sec

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

8 mm

Optical transmission

92%

UV protection

>99.90% Polymethyl methacrylate ALTUGLAS EX

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

Inlet for power cords

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 535 × 555 mm

Weight (net / gross)

23 / 33 kg

Optional table

T-4 (800 × 600 × 750 mm)

UVC/T-M-AR, DNA/RNA UV-cleaner box

3

Description

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

4 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

Inlet for power cords or optional 1x Built-in socket

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 535 × 555 mm

Optional table

T-4 (800 × 600 × 750 mm)

Weight (net / gross)

31 / 39 kg

UVT-B-AR, DNA/RNA UV-cleaner box

4

Description

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

5

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

2 mm

Thickness of upper front panel

8 mm

Thickness of screen

4 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

1 Built-in socket, max. 1000 W or optional inlet for power cords

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 585 × 555 mm

Optional table

T-4 (800 × 600 × 750 mm)

Weight (net / gross)

32 / 42 kg

UVT-S-AR, DNA/RNA UV-cleaner box

6

Description

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

7

Specially assigned moving tables T-4L (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

2x30W built‑in bactericidal, TUV30WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1 х 30W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-30W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

5 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

1200 × 520 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

3 Built-in sockets max. 1000 W

Nominal operating voltage

230 V, 50 Hz or 120 V, 60 Hz

Power consumption (230V / 120 V)

315 VA (1.4 A) / 530 VA (4.5 A)

Overall dimensions

1245 × 585 × 585 mm

Weight (net / gross)

58 / 68.5 kg

Optional table

T-4L (1290 × 600 × 770 mm)

Optional drawer unit

LF-1 (300 × 450 × 705 mm)


UVC/T-M-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV–cleaner box provide protection against contamination.

Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the box during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cleaner box during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal, TUV25WG13 UV-C
UV radiation level 15 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 4 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 650 × 475 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords or optional 1x Built-in socket, max. 1000 W (pls, order respectively)
Nominal operating voltage 100-240 V, 50/60Hz
Power consumption 67 W
Overall dimensions (W×D×H) 690 × 535 × 555 mm
Weight (net / gross) 28.8 / 39 kg
Optional table T-4 (800 × 600 × 750 mm)

UVT-B-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV–cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal, TUV25WG13 UV-C
UV radiation level 15 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 2 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 650 × 475 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords or optional 1x Built-in socket, max. 1000 W (pls, order respectively)
Nominal operating voltage 100-240 V, 50/60Hz
Power consumption 67 W
Overall dimensions (W×D×H) 690 × 585 × 555 mm
Optional table T-4 (800 × 600 × 750 mm)
Weight (net / gross) 31.2 / 42 kg

UVT-S-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the box during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4L (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV – cleaner box during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 2x30W built‑in bactericidal, TUV30WG13 UV-C
UV radiation level 15 mW / cm2 / s
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1 х 30W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-30W
Thickness of side panels 4 mm
Thickness of upper front panel 8 mm
Thickness of screen 5 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 1200 × 520 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit 3 Built-in sockets max. 1000 W
Nominal operating voltage 230 V, 50 Hz or 120 V, 60 Hz
Power consumption (230V / 120 V) 315 VA (1.4 A) / 530 VA (4.5 A)
Overall dimensions (W×D×H) 1245 × 585 × 585 mm
Weight (net / gross) 58 / 68.5 kg
Optional table T-4L (1290 × 600 × 770 mm)
Optional drawer unit LF-1 (300 × 450 × 705 mm)

Laminar Flow

Jisico

J-CBWV1, J-CBWV2 (Vertical type)

1

● High efficient dust removal is carried out by HEPA filter (99.97% efficiency on particle of 0.3μm).
● Air flow level is displayed in red (for filter change), yellow (filter change soon), green (filter in normal condition) colored 10 segment bar-graph LED display.
● UV lamps installed in workspace and air-path in back panel sterilize incoming fresh air.
● UV lamp is automatically turned off when glass door is opened to protect users.

Model

J-CBWV1

J-CBWV2

Type

Vertical type

Overall size (W×D×H)

mm

880×850×1,945

1,340×850×1,945

Inner size (W×D×H)

mm

780×630×720

1,240×630×720

Main filter

HEPA filter(99.97% efficient on particle of 0.3μ)

Filter efficiency (purity)

Class 100

FL lamp

W

20×1ea

40×1ea

Germicidal lamp (U.V.)

W

20×2ea

40×2ea

Fan motor

Hp

1/3

1/2

Air flowing volume

/min

16

32

Velocity

m/sec

0.5 ± 0.2

Utility

concent

AC 220V 1ea

gas cock

1ea

Window

Reinforced glass 5T

Material

working table

Stainless steel plate

cabinet

Steel plate with powder coated finish

Power source & consumption

AC 230V 50/60Hz 1Ø

AC 230V 50/60Hz 1Ø

Bio Safety Cabinet

JisicoJ-BSCV1, J-BSCV2

1

● Vertical type is used for jobs where ventilation of gases generated out of the experiments is required.
● Dust collection is carried out by HEPA filter (main filter).
● Approximately 70% of the HEPA-filtered air is circulated through the cabinet, while 30% passes through an exhaust HEPA filter and is
discharged.
● For vertical type, various instruments and equipment can be placed on the working-bench, for the air flow with negative pressure.
● Exact life span of filter is displayed in LCD display by adopting air flow sensor mode.
● Facility for working : A low-noise fan is attached in it and it is easy for working on account of flatten side of stay for working.
● Various facilities : It sterilizes the working space with ultraviolet lamp.

Model

J-BSCV1

J-BSCV2

Type

Class II A2

Overall size(W×D×H)

mm

 1,050×785×2,230/2,280

1,380×785×2,230/2,280

Inner size(W×D×H)

mm

900×645×730

1,230×645×730

Working size(W×D)

mm

860×475

1,190×475

Stand size(W×D×H)

mm

800×720×670/710

1,280×720×670/710

Main control

LCD microprocessor control with membrane touch type

Main filter

HEPA filter(99.97% efficient on particle of 0.3μ)
Option:ULPA filter(99.999% efficient on particle of 0.3μ)

FL lamp

W

20×1ea

40×1ea

Germicidal lamp(UV)

W

30×1ea

Air flowing volume

/min

45±5

Velocity

m/sec

0.5 ± 0.2

Illumination

Lux

More than 1,200

Blower motor

Hp

1/2

Door

Clear safety reinforced glass, 5mm thickness

Utility

socket

AC 220V 2ea

gas cock

1ea

Stand caster

Foot master

Material

working table

Stainless steel plate

cabinet

Steel plate with powder coated finish

Power source

AC 230V, 50/60Hz, 1phase

AC 230V, 50/60Hz, 1phase

Certification