UV Cabinet

UV Cabinet

Biosan

UVC/T-AR, DNA/RNA UV-cleaner box

1

Description

DNA/RNA UV-cleaner box UVC/T-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, plexiglas walls and working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

2

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Plexiglas: Polymethyl methacrylate ALTUGLAS EX

Working surface material

Steel with chemicals resistant powder coating

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

Radiation type

UV (λ = 253.7 nm), ozone-free

UV radiation level

15 mW / cm2 / sec

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

8 mm

Optical transmission

92%

UV protection

>99.90% Polymethyl methacrylate ALTUGLAS EX

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

Inlet for power cords

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 535 × 555 mm

Weight (net / gross)

23 / 33 kg

Optional table

T-4 (800 × 600 × 750 mm)

UVC/T-M-AR, DNA/RNA UV-cleaner box

3

Description

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

4 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

Inlet for power cords or optional 1x Built-in socket

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 535 × 555 mm

Optional table

T-4 (800 × 600 × 750 mm)

Weight (net / gross)

31 / 39 kg

UVT-B-AR, DNA/RNA UV-cleaner box

4

Description

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface painted with powder enamel or made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

5

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

1 x 25W built‑in bactericidal, TUV25WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1x25W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-15W

Thickness of side panels

2 mm

Thickness of upper front panel

8 mm

Thickness of screen

4 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

650 × 475 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

1 Built-in socket, max. 1000 W or optional inlet for power cords

Nominal operating voltage

100-240 V, 50/60Hz

Power consumption

67 W

Overall dimensions

690 × 585 × 555 mm

Optional table

T-4 (800 × 600 × 750 mm)

Weight (net / gross)

32 / 42 kg

UVT-S-AR, DNA/RNA UV-cleaner box

6

Description

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

7

Specially assigned moving tables T-4L (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (8,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material

Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)

Working surface material

Stainless steel

Open UV-lamp

2x30W built‑in bactericidal, TUV30WG13 UV-C

UV radiation level

15 mW / cm2 / sec

Radiation type

UV (λ = 253.7 nm), ozone-free

Digital time setting of direct UV exposure

0–24 hrs / non–stop (increment 1 min)

UV-recirculator

1 х 30W (efficiency >99% per 1 hour)

Daylight lamp (for working area illumination)

1 x TLD-30W

Thickness of side panels

4 mm

Thickness of upper front panel

8 mm

Thickness of screen

5 mm

Optical transmission

95%

UV protection

>96%, UV-protection film

Working area

1200 × 520 mm

Safety features

Automatic open UV-lamp switch off when screen is open

Power outlets inside the unit

3 Built-in sockets max. 1000 W

Nominal operating voltage

230 V, 50 Hz or 120 V, 60 Hz

Power consumption (230V / 120 V)

315 VA (1.4 A) / 530 VA (4.5 A)

Overall dimensions

1245 × 585 × 585 mm

Weight (net / gross)

58 / 68.5 kg

Optional table

T-4L (1290 × 600 × 770 mm)

Optional drawer unit

LF-1 (300 × 450 × 705 mm)


UVC/T-M-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVC/T-M-AR is designed for clean operations with DNA samples. UV–cleaner box provide protection against contamination.

Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the box during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV –cleaner box during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal, TUV25WG13 UV-C
UV radiation level 15 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 4 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 650 × 475 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords or optional 1x Built-in socket, max. 1000 W (pls, order respectively)
Nominal operating voltage 100-240 V, 50/60Hz
Power consumption 67 W
Overall dimensions (W×D×H) 690 × 535 × 555 mm
Weight (net / gross) 28.8 / 39 kg
Optional table T-4 (800 × 600 × 750 mm)

UVT-B-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVT-B-AR is designed for clean operations with DNA samples. UV-Cabinet provide protection against contamination.

Model is a bench-top type, made of metal framework, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the cabinet during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4 (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV–cabinet during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel, Sides: steel with chemical resistant powder coating Front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 1 x 25W built‑in bactericidal, TUV25WG13 UV-C
UV radiation level 15 mW / cm2 / sec
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1x25W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-15W
Thickness of side panels 2 mm
Thickness of upper front panel 8 mm
Thickness of screen 4 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 650 × 475 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit Inlet for power cords or optional 1x Built-in socket, max. 1000 W (pls, order respectively)
Nominal operating voltage 100-240 V, 50/60Hz
Power consumption 67 W
Overall dimensions (W×D×H) 690 × 585 × 555 mm
Optional table T-4 (800 × 600 × 750 mm)
Weight (net / gross) 31.2 / 42 kg

UVT-S-AR, DNA/RNA UV-cleaner box

Description

DNA/RNA UV-cleaner box UVT-S-AR is designed for clean operations with DNA samples. UV-cleaner box provide protection against contamination.

Model is a bench-top type, made of metal framework, glass walls, working surface made of stainless steel.

UV-cleaner boxes are equipped with an open UV lamp installed in the upper hood. UV-radiation from the open lamps disinfects the working area inactivating DNA/RNA fragments during 15–30 min of exposure. A digital timer controls duration of the direct UV irradiation. A daylight lamp provides proper illumination of the working surface.

UV-cleaner boxes are equipped with a flow-type bactericidal UV cleaner–recirculator AR, which provides constant decontamination inside the box during operation. They are recommended for operations with DNA/RNA amplicons.

UV cleaner–recirculator AR consists of a UV lamp, a fan and dust filters organized in a special body so that a user working with a UV-cleaner box is protected against UV light. Recirculator increases the maximum density of UV light making it  sufficiently effective for DNA/RNA inactivation. The UV–recirculator processes 100 UV-cleaner box volumes per hour, creating permanent aseptic conditions of operation inside the UV-cleaner box.

Specially assigned moving tables T-4L (with wheel locks) with a drawer are available on request.

Advantages of Biosan UV-cleaner boxes:

  • Ozone free high density UV decontamination
  • Long living UV lamps (9,000 hours average)
  • Automatic switch off of UV-lamps when the protective screen is opened
  • Bactericidal flow-type recirculator providing permanent decontamination inside UV – cleaner box during operation
  • Shockproof glass walls
  • Low noise, low energy consumption
  • Tables for installation of UV-cleaner boxes
  • UV-cleaner boxes with the bactericidal UV cleaner–recirculator AR is the patented Biosan solution

Specification

Walls material Rear: stainless steel Sides and front: glass (EUROGLASS, Germany)
Working surface material Stainless steel
Open UV-lamp 2x30W built‑in bactericidal, TUV30WG13 UV-C
UV radiation level 15 mW / cm2 / s
Radiation type UV (λ = 253.7 nm), ozone-free
Digital time setting of direct UV exposure 1 min–24 hrs / non–stop (increment 1 min)
UV-recirculator 1 х 30W (efficiency >99% per 1 hour)
Daylight lamp (for working area illumination) 1 x TLD-30W
Thickness of side panels 4 mm
Thickness of upper front panel 8 mm
Thickness of screen 5 mm
Optical transmission 95%
UV protection >96%, UV-protection film
Working area 1200 × 520 mm
Safety features Automatic open UV-lamp switch off when screen is open
Power outlets inside the unit 3 Built-in sockets max. 1000 W
Nominal operating voltage 230 V, 50 Hz or 120 V, 60 Hz
Power consumption (230V / 120 V) 315 VA (1.4 A) / 530 VA (4.5 A)
Overall dimensions (W×D×H) 1245 × 585 × 585 mm
Weight (net / gross) 58 / 68.5 kg
Optional table T-4L (1290 × 600 × 770 mm)
Optional drawer unit LF-1 (300 × 450 × 705 mm)

Share this post